Good news, part number JC1-A3-10-2 with NSN 5925004344178 is now available. This part number JC1-A3-10-2 is manufactured by Eaton Corporation and is described as Circuit Breaker. Do you need a quick quote for JC1-A3-10-2? We can help! Our ready-to-ship stock is comprised of over 2 billion NSN items.
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | SINGLE POLE TYPE |
| ADAQ | BODY LENGTH | 1.968 INCHES MINIMUM AND 2.032 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 0.718 INCHES MINIMUM AND 0.782 INCHES MAXIMUM |
| ADTV | CASE MATERIAL | PLASTIC |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.528 INCHES MINIMUM AND 1.592 INCHES MAXIMUM |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.628 INCHES MINIMUM AND 1.692 INCHES MAXIMUM |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.898 INCHES MINIMUM AND 1.962 INCHES MAXIMUM |
| AKPX | POLE QUANTITY | 1 |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC SINGLE LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SINGLE LOCATION |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC SINGLE LOCATION |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SINGLE LOCATION |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
| CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 22.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF |
| FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
| THSD | THREAD SERIES DESIGNATOR | UNC |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 QUICK DISCONNECT, MALE |
|
JC1-1 2 X 16
Flowserve Corporation 52374 Pin Straight Headle |
JC1-1 2 X 24
Flowserve Corporation 52374 Pin Straight Headle |
JC1-1-25-8N
Richey Inc 29309 Capacitor Fixed Ele |
JC1-1 4X12
Flowserve Corporation 52374 Pin |
|
JC1-1 4X12
Timken Gears And Services Inc 17454 Pin |
JC1-3 16X10
Flowserve Corporation 52374 Pin Straight Headle |
JC1-3 16X10
Flowserve Corporation 52374 Pin Straight Headle |
JC1 3 16X10
Flowserve Corporation 52374 Pin Straight Headle |
|
JC1 3 16X12
Flowserve Corporation 52374 Pin |
JC1-3 16X8
Flowserve Corporation 52374 Bushing Tapered |
JC1-3 16X8
Flowserve Corporation 52374 Bushing Tapered |
JC1-5 16X12
Flowserve Corporation 52374 Pin |
|
JC1-5 16X8
Flowserve Corporation 52374 Pin Straight Headle |
JC1-A3-4-2
Eaton Corporation 74193 Circuit Breaker |
JC1-A3-CA
Heinemann Electric Co Inc 1Y502 |
JC1-A3-CA-10-2
Eaton Corporation 74193 Circuit Breaker |
|
JC1-A3-CB-10-2
Eaton Corporation 74193 Circuit Breaker |
JC1-A3-CB-A
Heinemann Electric Co Inc 1Y502 |
JC1-A3-CB-A-8-3
Eaton Corporation 74193 Circuit Breaker |
JC1-A3-J-A
Heinemann Electric Co Inc 1Y502 |
|
JC1-A3-JB-A-30-2
Eaton Corporation 74193 Circuit Breaker |
JC1 A3CB 15 2
Eaton Corporation 74193 Circuit Breaker |
JC1-A8-A-5-10
Eaton Corporation 74193 Circuit Breaker |
JC1-A8CB-A-5-10
Eaton Corporation 74193 Circuit Breaker |
We Hope You'll Remember Us the Next Time If You’re Looking for NATO, Drone Parts.
Request for Quote