Good news, part number 9TC14 30 with NSN 5925010278134 is now available. This part number 9TC14 30 is manufactured by Sensata Technologies Inc and is described as Circuit Breaker. Do you need a quick quote for 9TC14 30? We can help! Our ready-to-ship stock is comprised of over 2 billion NSN items.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-027-8134 Item Description: CIRCUIT BREAKER | 5925 | 010278134 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 9TC14-30 | 2 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
| ABXD | BUSHING LENGTH | 0.250 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 1.100 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 2.350 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 1.350 INCHES NOMINAL |
| ADTV | CASE MATERIAL | PLASTIC |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.704 INCHES NOMINAL |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.780 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 3 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 30.0 AMPERES AC ALL LOCATIONS |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 AC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 145.0 ALL LOCATIONS |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
| CQJX | NOMINAL THREAD SIZE | 0.469 INCHES |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 4.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
| FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
| THSD | THREAD SERIES DESIGNATOR | UNS |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 SCREW |
|
9TC12-15
Zodiac Aerospace 3HZ89 Circuitbreaker |
9TC12-15
Sell Gmbh CH550 Circuitbreaker |
9TC12-20
Viking Air Ltd 48830 Circuit Breaker |
9TC14-1
Sensata Technologies Inc 82647 Circuit Breaker |
|
9TC14-15
Hawker Beechcraft Global Customer 08FU8 Breaker |
9TC14-15
Sikorsky Aircraft Corporation 0DX76 Circuit Breaker |
9TC14-15
Klixon |
9TC14-15
Raytheon Aircraft Services Inc 06HR3 |
|
9TC14-15
Sensata Technologies Inc 82647 Circuit Breaker |
9TC14-15
Textron Inc Breaker |
9TC14-15
Agusta Helicopter Circuit Breaker |
9TC14-20
Gulfstream Aerospace Corp 1T2T3 Circuit Breaker |
|
9TC14-20
Sikorsky Aircraft Corporation 0DX76 Circuit Breaker |
9TC14-20
Sensata Technologies Inc 82647 Circuit Breaker |
9TC14-25
Gulfstream Aerospace Corp 1T2T3 Brker |
9TC14-25
Agusta Helicopter Circuit Breaker |
|
9TC14-25
Texas Instrument Co 1G780 |
9TC14-25
Sensata Technologies Inc 82647 Circuit Breaker |
9TC14-25
Plasticam Sa B2647 Circuit Breaker |
9TC14-35
Gulfstream Aerospace Corp 1T2T3 Cktbr |
|
9TC14-35
Sensata Technologies Inc 82647 Circuit Breaker |
9TC2-1
Kapco Valtec Circuit Bre |
9TC2-15
Bombardier Corp 3AB48 Breaker Circuit 15 Amp |
9TC2-15
Sensata Technologies Inc 82647 Circuit Breaker |
We Hope You'll Remember Us the Next Time If You’re Looking for NATO, Drone Parts.
Request for Quote