Good news, part number JA3150V with NSN 5925009843009 is now available. This part number JA3150V is manufactured by Westinghouse Electric Corp and is described as Circuit Breaker. Do you need a quick quote for JA3150V? We can help! Our ready-to-ship stock is comprised of over 2 billion NSN items.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-00-984-3009 Item Description: Circuit Breaker | 5925 | 009843009 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | U | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| Ja3150v | 2 | 9 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
| ADAQ | BODY LENGTH | 10.138 INCHES NOMINAL |
| ADAT | BODY WIDTH | 5.500 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 3.812 INCHES NOMINAL |
| ADTV | CASE MATERIAL | PLASTIC |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 8.875 INCHES NOMINAL |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.719 INCHES NOMINAL |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 8.437 INCHES NOMINAL |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.719 INCHES NOMINAL |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJEC | BOSS HEIGHT | 0.500 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 3 |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 150.0 AMPERES AC ALL LOCATIONS |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 600.0 AC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 25000.0 AC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 170.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 460.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSE |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 50.0 DEG CELSIUS MAXIMUM ALL LOCATIONS |
| FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 SCREW |
|
JA3-218-8
Eaton Corporation 74193 Circuit Breaker |
JA3-241-3
Other J |
JA3-250-1
Eaton Corporation 74193 Circuit Breaker |
JA3-3
Kapco Valtec Ignitor All |
|
JA3-3 32X12
Flowserve Corporation 52374 Pin Cotter |
JA3-A2-2-10
Eaton Corporation 74193 Circuit Breaker |
JA3-A2-A3-A3-15-3
Eaton Corporation 74193 Circuit Breaker |
JA3 A2 A3 A3 AD 10 2
Eaton Corporation 74193 Circuit Breaker |
|
JA3-A2-A3-A3-AD-8-2
Eaton Corporation 74193 Circuit Breaker |
JA3-A2A3A3-10-2
Eaton Corporation 74193 Circuit Breaker |
JA3 A2A3A3 20 2
Eaton Corporation 74193 Circuit Breaker |
JA3 A2A3A3 A 10 2
Eaton Corporation 74193 Circuit Breaker |
|
JA3-A3-10-2
Eaton Corporation 74193 Circuit Breaker |
JA3-A3-10-20
Eaton Corporation 74193 Circuit Breaker |
JA3-A3-15-2
Eaton Corporation 74193 Circuit Breaker |
JA3-A3-25-3
Eaton Corporation 74193 Circuit Breaker |
|
JA3 A3 3 2
Eaton Corporation 74193 Circuit Breaker |
JA3-A3-A
Amp Inc 0BAR8 |
JA3-A3-A
Heinemann Electric Co Inc 1Y502 |
JA3 A3 A 10 2
Eaton Corporation 74193 Circuit Breaker |
|
JA3-A3-A-10-3
Other J |
JA3-A3-A-15-2
Eaton Corporation 74193 Circuit Breaker |
JA3-A3-A-20-2
Other J |
JA3 A3 A 20 3
Eaton Corporation 74193 Circuit Breaker |